| Products >> Technical Specifications for Security Block |
| |
| |
SIZE |
| |
Cabin may be designed as per customer’s specific requirements. However the typical sizes are as listed below : |
| |
Sr. No. |
Length (Feet) |
Width (Feet) |
Height (Feet) |
01 |
20’ |
08’ |
8.5’ |
02 |
20’ |
10’ |
8.5’ |
03 |
24’ |
08’ |
8.5’ |
04 |
24’ |
10’ |
8.5’ |
05 |
30’ |
08’ |
8.5’ |
06 |
30’ |
10’ |
8.5’ |
07 |
40’ |
08’ |
8.5’ |
08 |
40’ |
10’ |
8.5’ |
09 |
20’ |
20’ |
8.5’ |
|
|
| |
|
| |
FLOOR |
| |
 |
Heavy duty channel and angle grid structure to give rigidity. |
 |
Thick Marine-Ply / Fiber board / Duraboard for a durable base. |
 |
Homogenous anti-scratch PVC carpet over Marine Ply / Duraboard. |
|
| |
|
| |
WALLS |
| |
 |
2mm GI Sheets on the outside. |
 |
Pre-laminated board with ISI mark on the inside. |
 |
Cavity filled with special density thick insulation so as to avoid overheating of the cabin. |
|
| |
|
| |
ROOF |
| |
 |
Top comprises of 2mm thick steel sheets. Each sheet will have overlap on all sides and sheet will be fully welded using CO2 welding to prevent ingress of water. |
 |
Bottom shall be pre-laminated board. |
 |
Cavity filled with special density thick insulation to avoid overheating. |
 |
Air-gap shall be created in between the sheet and the insulation for further reduction in thermal conductivity using special Roof Cooling System. |
|
| |
|
| |
WINDOWS |
| |
 |
Powder coated Alu. Sliding Windows of standard size 4’ x 3’ with tinted glass. |
 |
Curtains / venation blinds may be provided for all / selected windows. |
 |
Weather shades over all windows. |
 |
Aluminum safety grills for windows may be provided. |
|
| |
|
| |
DOORS |
| |
 |
Doors shall be double skinned pressed steel with insulation. |
 |
Provided with Godrej cylindrical latch and door closer. |
 |
Aluminum powder coated Aldrop also shall be supplied for addnl. safety. |
 |
Weather shade shall be provided over the door. |
 |
Internal partition doors shall be wooden sliding type. |
|
| |
|
| |
ELECTRICLS |
| |
 |
All wiring shall be ISI marked. |
 |
Switches shall be ISI marked. |
 |
Concealed wiring shall be provided. |
 |
Main inlet plug adaptor for efficient and leak-proof flow of current. |
 |
MCB, ELCB shall be provided for additional safety. |
 |
Air-conditioning units may be provided wherever required. |
|
| |
|
| |
LEGS |
| |
 |
4/6/8 nos. legs as per cabin size, 6”/12”/18”/24” in height provided so as to hoist up the cabin. |
 |
Single step assembly provided |
|
| |
|
| |
FINISH |
| |
 |
Exterior : Matt finish UV resistant paint on top of special grade anti rust and elastic primer from specially recommended for GI (shade as per your choice). |
 |
Interior : Wooden / off-white finish laminate. |
|
| |
|
| |
LIFTING PROVISION |
| |
 |
Suitable top lifting. |
|
| |
|
| |
FURNITURE |
| |
 |
As per the customer’s specific requirement. |
|
| |
|