AHURA : Innovative shelter solutions........delivered
Products >> Technical Specifications for Residential Block
 
  SIZE
  Cabin may be designed as per customer’s specific requirements. However the typical sizes are as listed below :
 

Sr. No.

Length (Feet)

Width (Feet)

Height (Feet)

01

20’

08’

8.5’

02

20’

10’

8.5’

03

24’

08’

8.5’

04

24’

10’

8.5’

05

30’

08’

8.5’

06

30’

10’

8.5’

07

40’

08’

8.5’

08

40’

10’

8.5’

09

20’

20’

8.5’

   
 

FLOOR

 
Heavy duty channel and angle grid structure to give rigidity.
Thick Marine-Ply  / Fiber board / Duraboard for a durable base.
Homogenous anti-scratch PVC carpet over Marine Ply / Duraboard.
Custom made toilet blocks specially designed as per your versatile needs.
   
  WALLS
 
2mm GI Sheets on the outside.
Pre-laminated board with ISI mark on the inside.
Cavity filled with special density thick insulation so as to avoid overheating of the cabin.
The inner surface of the toilet area shall be finished with special 6mm PVC sheets with air gap for longer and better durability against constant exposure to water and acidic reaction.
 
  ROOF
 
Top comprises of 2mm thick steel sheets. Each sheet will have overlap on all sides and sheet will be fully welded using CO2 welding to prevent ingress of water.
Bttom shall be pre-laminated board.
Cavity filled with special density thick insulation to avoid overheating.
Air-gap shall be created in between the sheet and the insulation for further reduction in thermal conductivity using special Roof Cooling System.
   
  WINDOWS
 
Powder coated Alu. Sliding Windows of standard size 4’ x 3’ with tinted glass.
Curtains / venation blinds may be provided for all / selected windows.
Weather shades over all windows.
Aluminum safety grills for windows may be provided.
   
 

DOORS

 
Doors shall be double skinned pressed steel with insulation.
Provided with Godrej cylindrical latch and door closer.
Aluminum powder coated Aldrop also shall be supplied for addnl. safety.
Weather shade shall be provided over the door.
Internal partition doors shall be wooden sliding type.
The inner doors of the toilet block shall be PVC doors so as to provide longer and better durability against constant exposure to water and acidic reaction.
Louvered ventilators shall be provided for removal of foul air from the toilet area.
   
  ELECTRICLS
 
All wiring shall be ISI marked.
Switches shall be ISI marked.
Concealed wiring shall be provided.
Main inlet plug adaptor for efficient and leak-proof flow of current.
MCB, ELCB shall be provided for additional safety.
Air-conditioning units may be provided wherever required.
Louvered exhaust fans for removal of foul air in the toilet area.
   
  LEGS
 
4/6/8 nos. legs as per cabin size, 6”/12”/18”/24” in height provided so as to hoist up the cabin.
Single step assembly provided
   
  FINISH
 
Exterior : Matt finish UV resistant paint on top of special grade anti rust and elastic primer from specially recommended for GI (shade as per your choice).
Interior  : Wooden / off-white finish laminate. 6mm PVC sheet for the toilet area (shade as per your choice).
   
  LIFTING PROVISION
 
Suitable top lifting.
   
  FURNITURE
 